Archi Automate 27.23 · Updated 31 August 2026
Connect Archi Automate to Autodesk Forma and ACC/BIM 360
This guide contains the Autodesk-side administrator setup and the user-side MCP connection steps. The public identifiers below are required configuration values, not passwords or client secrets.
Public integration identifiers
| Value | Use |
|---|---|
| APS application | Archi Automate |
| APS Client ID | NzaIlycoSd2iK0cj1K3JDeX4Wzz3zy2yxIgRsquL3xi7CIHT |
| Forma extension | Archi Automate |
| Forma extension ID | b101cba9-fad5-4375-8a93-c9fb06f54f2f |
| OAuth callback | http://localhost:53750/forma/callback (local loopback on the user's computer) |
Archi extension admin
Owns and configures the shared Forma extension and allow-lists customer projects.
Customer Autodesk admin
Installs the prepared Forma extension or adds the ACC Custom Integration.
Normal user
Restarts the AI client, completes Autodesk consent, and selects/registers the project.
Autodesk Forma
pro_… ID from the design-mode URL, and send it to Archi support. The Archi extension administrator must allow-list that project unless the extension is enabled for all Forma users. Do not create a second APS app or replacement extension.1. Archi prepares the extension once
- Create/configure the Archi Automate Forma extension from a Forma-licensed account and accept the App Store Publisher Agreement.
- Set Owner to the APS application Archi Automate. If the Forma administrator uses a different Autodesk account from the APS app owner, first add that account as an Editor collaborator on the APS application.
- Add the APS Client ID above to Service accounts.
- Allow the customer's
pro_…project, or choose All users of Forma. An empty Only specific projects list blocks installation even for the extension creator. - Complete Owner, Service accounts, and project grants before installation.
The extension does not have to be marketplace-published for an explicitly allow-listed project. Publishing controls general marketplace discovery.
2. The customer's Forma project admin installs it
- Open the target Forma site.
- Open App Store → Archi Automate → Add → Agree.
- If Service accounts or project grants change later, remove and reinstall the extension. Forma snapshots those grants at installation.
3. The user connects the MCP tools
- Install Archi Automate 27.16 or later (27.23 is current). In Hub, connect the AI client, then fully restart/reconnect it so the MCP tool list reloads.
- Open the project in Forma Site Design and copy the
pro_…ID from the design-mode URL. Do not use theup_…overview ID. - Run
forma_ping. - If disconnected, run
forma_connectand complete Autodesk browser consent. - Run
forma_add_projectwith thepro_…ID. Archi Automate checks US and EMEA. - Verify with
forma_list_sessionsandforma_list_documents.
OAuth success alone does not grant project access. A persistent 403 AccessDenied normally means the extension is not allowed/installed for that exact project, was installed before its grants were configured, or the wrong project ID/region is being used.
Capability note: Archi Automate can contribute integrate geometry such as footprint-and-height massing or GLB, but it does not author every Forma-native object or native floor-stack building. Forma exposes no unrestricted native delete endpoint.
Autodesk Construction Cloud and BIM 360
ACC/BIM 360 does not use the Forma extension ID. The Autodesk account administrator adds a Custom Integration using the APS application name and Client ID above.
1. The Autodesk account admin authorizes Archi Automate
- Open Autodesk Account Admin for the target ACC or BIM 360 account.
- Go to Settings → Custom Integrations → Add Custom Integration.
- Enter app name
Archi Automateand Client IDNzaIlycoSd2iK0cj1K3JDeX4Wzz3zy2yxIgRsquL3xi7CIHT. - Grant Document Management. Also grant Account Administration when project creation or membership management is required.
- Save and repeat for every Autodesk account/hub the users need. Accounts in different data regions must be authorized separately.
2. The user connects the MCP tools
- Restart/reconnect the AI client after installing or updating Archi Automate.
- Run
acc_ping. - If disconnected, run
acc_connectand complete Autodesk browser consent. - Run
acc_list_sessions, thenacc_list_projectsandacc_list_documents.
If sign-in succeeds but a hub is missing, the Custom Integration is normally absent from that exact Autodesk account/region, or the signed-in user lacks membership. Adding it to one hub does not authorize another.