Evaluate daylight professionally in every phase of your project, against TEK17, BFS 2024:8, BR18, BRE 209, EN 17037 and more, directly in your Revit model. Move, resize, add or delete a window and see the result.
archi Daylight is daylight simulation software for Revit from Archi Systems AS. Analyse daylight factor without a weather file, and climate-based daylight (DA, sDA, UDI, ASE) with your project's weather file, plus sunlight, view out, glare and solar radiation, and check them against the rules your project needs; some schemes give figures only.
The classic check most national rules ask for: how much of the outdoor daylight reaches each point of the room under an overcast sky. No weather data needed.
Daylight autonomy (DA), spatial daylight autonomy (sDA), useful daylight illuminance (UDI) and annual sunlight exposure (ASE), from the real sun and sky of your location, hour by hour over the year.
Used by
BR18 §379EN 17037, illuminance methodCAM 2.3.7, new build and schoolsUK National Annex, dwellingsBREEAM International V7, officesNordic Swan, method 2LEED sDA and ASE · figuresWELL · figures
Zurich office · L05 · 3D
Daylight factor · L05 · 3D view · Zurich office sample study
From model to report
One decision, from model to report
01
Place or move a windowWork in your own Revit model. No export to another program.
02
See the new valuesWith Live on, move, resize, add or delete a window and the daylight values update.
03
Check the room against the ruleEach room shows Pass or Fail, or figures where the scheme gives no verdict.
04
State it for the authorityThe report gives the result, what the rule set does not cover, and how each analysis was calculated.
Every phase, one tool
From early model to submission
01 · Early design
Early checks on the first model
Test the site and the first plans for daylight and sun before the design is fixed.
02 · Developed design
Every room against the rule
As rooms and windows take shape, see each room's result against the rule you chose, level by level.
03 · Submission
The documented result
Run the final calculation and hand the report to the client, the authority or the certifier.
Rules per country
TEK17, BFS 2024:8, BR18, BRE 209 and EN 17037 checks in Revit
Choose a country on the map to see the rules archi Daylight checks there, what each one checks, and whether it gives Pass or Fail, figures only, or is not judged yet.
PASS / FAILjudged per room or dwellingFIGURES ONLYno verdictNOT JUDGED YETfigures only in 27.1
Europe · select a country
Beyond Europe
National rules that give Pass or FailNo national verdict: figures only or not judged yet; EN 17037 or international schemes give the verdict where offeredNo national rule set: EN 17037 or international schemes
TEK17 §13-7, preaccepted performance 1aDaylight factorRoom average daylight factor of at least 2.0 % over the NS-EN 12464-1 4.4 area.PASS / FAIL
BREEAM-NOR v6.1.1 Hea 01Daylight factorMinimum and Medium daylight-factor levels per room, and the credits that follow.PASS / FAIL
Nordic Swan Ecolabel 089, O35Daylight factor or climate-basedOffices and educational buildings: every applicable room against the national target (1.8 % or 200 lx).PASS / FAIL
EN 17037 at OsloDaylight factorDaylight-factor targets for the site, levels Minimum, Medium and High.PASS / FAIL
BFS 2024:8, 4 kap. 1 §Daylight factorDaylight factor of at least 1.0 % over at least half the dwelling's area for continuous stay. One verdict per dwelling.PASS / FAIL
BFS 2024:8, 4 kap. 2 §View outView out from living and dining spaces, confirmed per room.PASS / FAIL
Nordic Swan Ecolabel 089, O35Daylight factor or climate-basedOffices and educational buildings: every applicable room against the national target (1.8 % or 200 lx).PASS / FAIL
EN 17037 at StockholmDaylight factorDaylight-factor targets for the site, levels Minimum, Medium and High.PASS / FAIL
BR18 §379, dwellingsClimate-basedAt least 300 lx over half of each room for at least half the daylight hours.PASS / FAIL
BR18 §379, work rooms and institutionsClimate-basedThe same 300 lx rule over the area you nominate.PASS / FAIL
Nordic Swan Ecolabel 089, O35Daylight factor or climate-basedOffices and educational buildings: every applicable room against the national target (2.1 % or 300 lx).PASS / FAIL
EN 17037 at CopenhagenDaylight factorDaylight-factor targets for the site, levels Minimum, Medium and High.PASS / FAIL
Not covered: the glass-area route, the bedroom allowance and §380 exemptions.
Finland
National rules that give Pass or Fail
RTS environmental classification and the Nordic and international schemes.
RTS S2.1Daylight factorRoom average of at least 2.2 % with more than 0.7 % over 95 % of the plane; levels by the share of rooms that pass.PASS / FAIL
Nordic Swan Ecolabel 089, O35Daylight factor or climate-basedOffices and educational buildings: every applicable room against the national target (1.8 % or 200 lx).PASS / FAIL
BREEAM International V7, Hea 01Climate-basedOffices only. Routes 1 and 2 judge; route 3 (sDA) is not judged yet.PASS / FAIL
EN 17037 at HelsinkiDaylight factorDaylight-factor targets for the site, levels Minimum, Medium and High.PASS / FAIL
Iceland
No national verdict: figures only or not judged yet
No national verdict yet: Nordic Swan and EN 17037 at Reykjavik give the verdict.
Byggingarreglugerð 10.4.4, dwellingsClimate-basedIlluminance figures per dwelling are shown; the verdict is not given yet.NOT JUDGED YET
Nordic Swan Ecolabel 089, O35Daylight factor or climate-basedOffices and educational buildings: every applicable room against the national target (2.6 % or 300 lx).PASS / FAIL
EN 17037 at ReykjavikDaylight factorDaylight-factor targets for the site, levels Minimum, Medium and High.PASS / FAIL
Germany
No national verdict: figures only or not judged yet
No national verdict yet: EN 17037 at Berlin gives the verdict.
CAM 2.3.7, new buildClimate-based300 lx over 50 % and 100 lx over 95 % of the plane for half the daylight hours; at least 75 % of rooms must pass.PASS / FAIL
CAM 2.3.7, schoolsClimate-based500 lx over 50 % and 300 lx over 95 %, every room.PASS / FAIL
CAM 2.3.7, renovationDaylight factorRoom average daylight factor above 2.0 % (above 3.0 % in schools).PASS / FAIL
DM 5 luglio 1975, art. 5Daylight factorDwellings: room average daylight factor of at least 2.0 %.PASS / FAIL
EN 17037 at Rome has no target value: use the weather-file basis.
Netherlands
National rules that give Pass or Fail
Schools and BREEAM-NL.
Zurich office · L01 · plan
Daylight factor · L01 plan · Zurich office sample study
Rule or schemeChecksWhat is checkedResult
Frisse Scholen 2021Daylight factorDaylight factor over more than 50 % of every classroom you confirm. Class C; classes B and A use thresholds not yet verified against the RVO text.PASS / FAIL
BREEAM-NL HEA 01Climate-basedIlluminance figures per room; no points awarded yet.NOT JUDGED YET
EN 17037 at Amsterdam has no target value: use the weather-file basis.
United Kingdom
National rules that give Pass or Fail
Daylight and sunlight for planning, with the values BRE 209 gives.
Zurich office · facades NE
Vertical sky component · facades from north-east · Zurich office sample study
Rule or schemeChecksWhat is checkedResult
UK National Annex to BS EN 17037, dwellingsClimate-basedIlluminance by room type (bedroom, living room, kitchen), as BRE 209 states the values.PASS / FAIL
UK National Annex, daylight-factor routeDaylight factorBy location, from St Peter (Jersey) to Aberdeen.PASS / FAIL
BRE 209 3.1, sunlight in new dwellingsSunlightAt least one habitable room with 90 minutes of sun on 21 March.PASS / FAIL
BRE 209 2.2.7, VSC at existing windowsVertical sky componentBefore and after, from two runs.PASS / FAIL
BRE 209, no-sky lineNo-sky lineBefore and after, from two runs.PASS / FAIL
BRE 209 3.3, sunlight on amenity areasSunlightTwo hours on 21 March over half of each area, or 0.80 of the former area.PASS / FAIL
BRE 209 3.2, APSHSunlightFigures from the run's weather file; not judged yet.NOT JUDGED YET
EN 17037 at LondonDaylight factorDaylight-factor targets for the site, levels Minimum, Medium and High.PASS / FAIL
Ireland
National rules that give Pass or Fail
Dwellings by the Compact Settlements Guidelines, offices by BREEAM International.
Zurich office · L01 · plan
Daylight autonomy · L01 plan · Zurich office sample study
Rule or schemeChecksWhat is checkedResult
Compact Settlements Guidelines 5.3.7(b), dwellingsClimate-basedThe UK National Annex rule, plane and room types.PASS / FAIL
BREEAM International V7, Hea 01Climate-basedOffices only. Routes 1 and 2 judge; route 3 (sDA) is not judged yet.PASS / FAIL
EN 17037 at Dublin has no target value: use the weather-file basis.
Belgium, Spain, Poland
No national rule set: EN 17037 or international schemes
BREEAM International V7 for offices. Poland's national sunlight rule gives figures only.
Zurich office · L01 · plan
Sunlight exposure · L01 plan · Zurich office sample study
Rule or schemeChecksWhat is checkedResult
BREEAM International V7, Hea 01Climate-basedOffices only. Routes 1 and 2 judge; route 3 (sDA) is not judged yet.PASS / FAIL
Poland: WT 2002 § 60, sunlightSunlightRepealed rule; figures only.FIGURES ONLY
EN 17037 at Brussels, Madrid and Warsaw has no target value: use the weather-file basis.
Switzerland, Austria
No national rule set: EN 17037 or international schemes
No national rule set. EN 17037 on your weather file gives the verdict.
Zurich office · L01 · plan
Annual sunlight exposure · L01 plan · Zurich office sample study
Rule or schemeChecksWhat is checkedResult
EN 17037 on the run's weather fileDaylight factorTargets from the file's own data, its name and checksum stamped on the run.PASS / FAIL
EN 17037, illuminance methodClimate-based300/100 lx, 500/300 lx or 750/500 lx for half the daylight hours.PASS / FAIL
EN 17037 at Vienna and Bern has no target values: use the weather-file basis.
Australia
National rules that give Pass or Fail
NCC, New South Wales and Victoria.
Zurich office · facades NW
Sunlit time · facades from north-west · Zurich office sample study
Rule or schemeChecksWhat is checkedResult
NCC Volume One F6P1Daylight factorRoom average daylight factor of at least 2 %, in the building classes F6P1 lists.PASS / FAIL
NSW ADG 4A-1, solar accessSunlightShare of apartments with 2 or 3 hours of sun on 21 June.PASS / FAIL
NSW ADG 3D-1, communal open spaceSunlightHalf the principal usable part in sun for 2 hours on 21 June.PASS / FAIL
BESS-10 (Victoria)Daylight factor or climate-basedDaylight factor and winter daylight autonomy per room type.PASS / FAIL
Victoria apartment guidelines, room depthRoom depthInformation only.NOT JUDGED YET
United States, Canada, Japan
No national verdict: figures only or not judged yet
LEED and WELL, also last in every country's menu. No compliance verdict.
Zurich office · L01 · plan
Spatial daylight autonomy · L01 plan · Zurich office sample study
Rule or schemeChecksWhat is checkedResult
LEED v4.1Climate-basedsDA and ASE figures and indicative points.FIGURES ONLY
LEED v5Climate-basedsDA figures.FIGURES ONLY
WELLClimate-basedIndicative figures.FIGURES ONLY
Anywhere in Europe: EN 17037
No national rule set: EN 17037 or international schemes
EN 17037 at a listed site, or on any weather file.
EN 17037, daylight-factor methodDaylight factorMinimum, Medium and High levels at Oslo, Stockholm, Copenhagen, Helsinki, Reykjavik, Berlin, Paris, London or Prague.PASS / FAIL
EN 17037 on the run's weather fileDaylight factorTargets from the file's own data, its name and checksum stamped on the run.PASS / FAIL
EN 17037, illuminance methodClimate-based300/100 lx, 500/300 lx or 750/500 lx for half the daylight hours.PASS / FAIL
EN 17037, sunlight exposureSunlightPer dwelling. Verdict at Minimum (1:30); levels 3:00 and 4:00 shown.PASS / FAIL
EN 17037, view outView outPer room, at the run's level.PASS / FAIL
EN 17037, glareGlareFigures only: DGP and the share of hours above each threshold.FIGURES ONLY
Vienna, Bern, Amsterdam, Brussels, Rome, Madrid, Warsaw and Dublin have no target values: use the weather-file basis.
Live
Change the model, see the result
Turn on Live and keep designing in Revit. Move, resize, add or delete a window and the daylight values update.
Daylight, sunlight and solar analyses of the Zurich office
AI-generated visualisation
Building view · aerial · Zurich office · AI-generated visualisation
One model, inside and out.
AI-generated visualisation
Building view · garden facade · AI-generated visualisation
AI-generated visualisation
Building view · open office · AI-generated visualisation
In the rooms: climate-based daylight and sunlight
L01 · 3D
Daylight autonomy · L01 · 3D
L01 · 3D
Useful daylight illuminance · L01 · 3D
L01 · 3D
Annual sunlight exposure · L01 · 3D
L01 · 3D
Sunlight exposure · L01 · 3D
On the facades and the site: sunlit time, vertical sky component, solar radiation
Facades · north-west
Sunlit time · facades from north-west
Facades · north-east
Vertical sky component · facades from north-east
Site · 3D
Solar radiation · site with neighbours
Report
A report for the client and the authority
Every room against the rule you chose, with its result: Pass or Fail, or figures where the scheme gives no verdict.
What the rule set does not cover, stated in its own line.
How each analysis was calculated, named in the report.
In seven languages: English, Norwegian, Swedish, Danish, German, Italian and French.
Validation records
Validated against CIE 171 test cases and Radiance
Our own runs of the CIE 171 test cases, by calculation route. At Final, every analysis runs on Radiance. At Preview and Standard, eleven analyses use the GPU engine when your graphics card supports it, each checked against Radiance; annual DA, sDA and UDI stay on Radiance.
Route
Quality
Cases
Result
Radiance
Final
9
9 PASS in 3 runs, every point in band
Radiance
Standard
8
8 PASS in 5 runs, every point in band
GPU engine
Preview, Standard
52
52 PASS every CIE 171 case the GPU engine handles passes
Our own runs of the CIE 171 test cases, not a certification. Case numbers and our values only; the standard's text is not reproduced. Every GPU acceptance run used one card model, an NVIDIA GeForce RTX 5070. GPU and Radiance results agree within stated tolerances, not bit for bit. Full records, including every route and case, on request.
Pricing
Floating or desktop, for 1 month, 1 year or 3 years
Prices in USD. A floating licence is a seat shared across the office; a desktop licence is bound to one computer.
Daylight factor, daylight autonomy (DA), spatial daylight autonomy (sDA), useful daylight illuminance (UDI), direct sun for ASE, sunlight hours for rooms, facades and outdoor spaces, view out, vertical sky component (VSC), glare (DGP) and solar radiation.
Does it check my country's rules?
Choose the country on the map; its panel shows which rules give Pass or Fail. Germany and France: EN 17037 at Berlin or Paris gives the verdict. Iceland: Nordic Swan, or EN 17037 at Reykjavik. Poland: BREEAM International V7, offices only. Switzerland and Austria: EN 17037 on your weather file.
What is the difference between floating and desktop?
A floating licence is a seat shared across the office. A desktop licence is bound to one computer.
How do I install it for the office?
Use the setup program, a silent installation, msiexec or managed deployment. On every path the installer will not start while Revit is running, and it leaves an add-in file that is not archi Daylight's untouched. Updates then come through Archi Updater, which downloads only the files that changed and does nothing while Revit runs.
Which calculation engine does it use?
Radiance, the industry reference, for the final calculation and, at every quality level, for climate-based annual DA, sDA and UDI. At Preview and Standard, eleven analyses use a GPU engine checked against Radiance when your graphics card supports it, among them window-group light and sun (sDA with blinds, per window group); otherwise Radiance runs them. The report names which engine ran each analysis.
Do I need a graphics card?
No. Without a supported card, Radiance runs every analysis.
Is it certified against CIE 171?
No. CIE 171 gives test cases, and we publish our own runs of them: validated, not certified.
Which languages are the screens and reports in?
English, Norwegian, Swedish, Danish, German, Italian and French.